Nitrogen Danmark
Total Organic Carbon Analyzer BK-TOC1500 & BK-TOC1700New Products

BB-48954601

Total Organic Carbon Analyzer BK-TOC1500 & BK-TOC1700

BK-TOC1700 is able to work under on-line mode to realize real-time monitoring

Price on requestPrice agreed individually — contact us.

Specifications

  • Detection Range0.001~1.5mg/l
  • Detection Limit1ppb
  • Max Tolerance士5%
  • Analysis Time3 min
  • Response TimeWithin 10 min
  • Sample Temperature1~95°C
  • Sample Flow Speed3ml/min
  • Repeatability Tolerance≤3%
  • Drifting士5%
  • Environment Temperature10-40℃ with temperature change士5℃/d
  • Relative Humidity≤85%
  • Power SupplyAC 220V, 50/60Hz (Standard); AC 110V, 50Hz (Optional)
  • Consumption100W

Details

Features: • Equipped with conductivity detector to quantify TOC concentration. • BK-TOC1700 is able to work under on-line mode to realize real-time monitoring • Ideal choice to measure and monitor microelectronics water, purified water, water for injection, etc. • Automatic sample introduction with one-button setting, no sample contamination, no harm on operator and environment • UV oxidation by UV lamp, no need to add acid, gas or catalytic, greatly reduces the experiment and maintenance cost • 7 inches touch screen with smart UI, easy to operate and read test data • In compliance with FDA-21 CFR Part11 requirements and USP, EP, JP and CHP • Auto sampler is optional according to different experiment requirements • Online and offline mode can be easily switched. (BK-TOC1700) • 8GB large storage capacity, no restriction of data and time • Quick test, each analysis takes less than 3 minutes • All historical records can be traced by searching test date • Data can be retrieved and saved to USB directly • Equipped with Bluetooth printer for quick and easy data printing • Modular design for quick installation and easy maintenance Parameter: Model BK-TOC1500 BK-TOC1700 Work Model Offline Online and offline Detection Range 0.001~1.5mg/l Detection Limit 1ppb Max Tolerance 士5% Analysis Time 3 min Response Time Within 10 min Sample Temperature 1~95°C Sample Flow Speed 3ml/min Repeatability Tolerance ≤3% Drifting 士5% Environment Temperature 10-40℃ with temperature change士5℃/d Relative Humidity ≤85% Power Supply AC 220V, 50/60Hz (Standard); AC 110V, 50Hz (Optional) Consumption 100W External Size(L*W*H) 440*220*300mm 440*220*405mm Net Weight 11kg 12.25kg Package Size(L*W*H) 610*470*405mm 640*490*440 mm Gross Weight 16kg 18kg

Total Organic Carbon Analyzer BK-TOC1500 & BK-TOC1700 | Nitrogen Danmark